Senva UL Listed TG Series sensors can be ordered as individual CO or NO2 sensors or as a combination of CO&NO2 sensors in a shared enclosure. CO and NO2 sensor components are listed to UL2075. The analog output model features 2 outputs that support daisy chain wiring - multiple sensors may be used in a parallel sequence (0-10V) for cost effective coverage of large areas. The unit can also act as a stand alone controller, utilizing the relay for exhaust fan operation or the output for direct control of a VFD. The BACnet/Modbus model supports BACnet MS/TP & Modbus network communication in one unit. Standard features include network auto-configuration, a programmable fan relay, LED indicators, integrated display and audible alarm.
TG UL Combustibles Wall & Duct
Senva TG Series sensors can be ordered as individual CH4 sensor, C3H8 sensor, H2 sensor, O2 sensor, H2S sensor, or specify two sensing elements in one enclosure including CO and NO2. The analog output model features 2 outputs that support daisy chain wiring - multiple sensors may be used in a parallel sequence (0-10V) for cost effective coverage of large areas. The unit can also act as a stand alone controller, utilizing the relay for exhaust fan operation or the output for direct control of a VFD. Order the NEW fail-open relay version for streamlined integration into fire control panels. The BACnet/Modbus model supports BACnet MS/TP & Modbus network communication in one unit. Standard features include network auto-configuration, a programmable two-staged relays, LED indicators, integrated display and audible alarm.
Senva TG Series refrigerant sensors are a great solution for refrigerant leak detection in many applications. It can be ordered as individually calibrated R134A or R410A sensors or any combination with CO or NO2 sensors. Buy pre-calibrated for R134A or R410A or factory calibrate to any refrigerant including R134A, R410A, R407C, R404A, R22, R123. The analog output model features 2 outputs that support daisy chain wiring - multiple sensors may be used in a parallel sequence (0-10V) for cost-effective coverage of large areas. The unit can also act as a stand-alone controller, utilizing the relay for exhaust fan operation or the output for direct control of a VFD. The BACnet/Modbus model supports one unit of MS/TP & Modbus network communication. Standard features include network auto-configuration, a programmable fan relay, LED indicators, an integrated display, and an audible alarm.
Senva TGR Series sensors can be ordered as individual CO or NO2 sensors or as a combination CO/NO2 sensor in a shared enclosure. Choose up to two from a variety of refrigerant gases, combustibles, or Carbon Monoxide for a combination of air quality and toxic gas detection. The analog output model features 2 outputs that support daisy chain wiring - multiple sensors may be used in a parallel sequence (0-10V) for cost effective coverage of large areas. The unit can also act as a stand alone controller, utilizing the relay for exhaust fan operation or the output for direct control of a VFD. The BACnet/Modbus model supports BACnet MS/TP & Modbus network communication in one unit. Standard features include a programmable fan relay, LED indicators, integrated display and audible alarm.