Gasket seals sensor against wall drafts and false readings
Senses thousands of contaminants
Perfect alternative or compliment to CO2 sensing for ventillation
Recessed design is attractive and durable
New enclosure design is rugged and slim
No exposed screws; unobtrusive tamper resistant design
Ideal for cafeterias, conference rooms, restrooms and public environments
Simple and versatile
Fits easily in standard single gang boxes
45 degree terminals for ease of wiring
Saves installation time and reduces callbacks
Choose from a range of options
0-5V, 0-10V, 2-wire and 3-wire 4-20mA options
Thermistor outputs for temperature optional
Applications
Controlling ventilation in response to occupancy
Ventillation control
Economizer control
Cafeterias, conference rooms, restrooms and public assembly areas
The VT0R is capable of sensing thousands of VOC’s coming from sources such as paints, glues, cleaners, alcohol, building products, smoke, and myriad other harmful or offensive gases. It’s ability to sense these contaminants in addition to breath and other bodily funcitons makes it the preferred alternative or compliment to CO2 occupancy sensing. The VT0R Value Series ensures that odor and ventilation issues are never a topic of conversation. An array of analog outputs and thermistor options accommodate any installation and keep occupants breathing easy.
Gasket seals sensor against wall drafts and false readings
Senses thousands of contaminants
Perfect alternative or compliment to CO2 sensing for ventillation
Recessed design is attractive and durable
New enclosure design is rugged and slim
No exposed screws; unobtrusive tamper resistant design
Ideal for cafeterias, conference rooms, restrooms and public environments
Simple and versatile
Fits easily in standard single gang boxes
45 degree terminals for ease of wiring
Saves installation time and reduces callbacks
Choose from a range of options
0-5V, 0-10V, 2-wire and 3-wire 4-20mA options
Thermistor outputs for temperature optional
SPECIFICATIONS
Power Supply
12-30VDC/24VAC (1), 24mA max.
Outputs
RH% (options)
3-wire 0-5/10VDC, 4-20mA 2-wire 4-20mA
Output scaling
RH%
0-500 (relative intensity)
Thermistor Options
Yes, see ordering table
Sensor Performance
Type
MOS
Gas
Ethanol
Range
0-1000ppm of ethanol equivalent
Response time
<10s
Humidity Compensation
Yes
Long term drift
<0.25%RH per year
Enclosure
Dimensions
4.45"h x 2.7"w x 0.5"d (depth from wall)
RH Rating
0-90% operating, 0-80% storage
Temp Rating
-10 to 50C operating, 5 to 30C storage
Compliance
CE, RoHS
One side of transformer, secondary is connected to signal common. Dedicated transformer is recommended. 15-30VDC/24VAC power supply voltage required for 10 volt output.