NEW PRODUCTS

P4 Precision Dry Pressure

P4 Precision Dry Pressure

Now with NIST calibrated 0.25% and 0.50% accuracy options, the P4 dry media pressure transmitter features fixed ranges optimized for building (zone) pressure, filter measurement, and static duct applications.   Innovative static probe integrates with unit or can be mounted remotely for static pressure.  PATENT PENDING. CALL FOR SPECIAL PRICING

CO Recessed Value

CO Recessed Value

Designed to maximize safety in work and school environments, the TG0R Value Series features a UL2034 recognized CO sensor . Audible buzzer, relay output and end-of-life indication. Choose the analog output that works best for each job.

Value Refrigerant, Recessed

Value Refrigerant, Recessed

Designed for your VRF systems--ideal for hotel rooms and other environments requiring local leak detection. Local audible buzzer alarm, end-of-life indication for sensor element, and test function. Features a choice 0-5V, 0-10V, and 3-wire 4-20mA and thermistor outputs. Integrated alarm relay.

TotalSense PM/VOC/CO2/RH/T/PIR Wall

TotalSense PM/VOC/CO2/RH/T/PIR Wall

The TotalSense Series provides more data for more advanced ventilation control while drastically reducing installation cost and time on a project. It includes a comprehensive selection of IAQ sensing with carbon dioxide (CO2), relative humidity (RH), and temperature plus options for occupancy detection (PIR), total volatile organic compounds (TVOC), particulate matter (PM) and ambient light. More than an IAQ sensor, it’s the first fully configurable Indoor Environmental Quality (IEQ) sensor matrix. Motion detection (PIR) can initiate ventilation upon occupancy, providing air exchanges the instant people are present (in addition to monitored elevated CO2 levels.) This technology provides a much faster trigger for ventilation allowing for cleaner and safer indoor spaces while still saving energy. PIR and ambient light sensors can also be utilized for light harvesting for additional energy savings and code compliance.

TotalSense CO2/RH/T/PIR Wall

TotalSense CO2/RH/T/PIR Wall

The TotalSense Series provides more data for more advanced ventilation control while drastically reducing installation cost and time on a project. It includes a comprehensive selection of IAQ sensing with carbon dioxide (CO2), relative humidity (RH), and temperature plus options for occupancy detection (PIR), total volatile organic compounds (TVOC), particulate matter (PM) and ambient light. More than an IAQ sensor, it’s the first fully configurable Indoor Environmental Quality (IEQ) sensor matrix. For options including PM or TVOC or for RH/Temp only, see the other TotalSense webpages in the "indoor air quality" or "relative humidity"section or call your sales rep. Motion detection (PIR) can initiate ventilation upon occupancy, providing air exchanges the instant people are present (in addition to monitored elevated CO2 levels.) This technology provides a much faster trigger for ventilation allowing for cleaner and safer indoor spaces while still saving energy. PIR and ambient light sensors can also be utilized for light harvesting for additional energy savings and code compliance.

CO2/Temp Recessed

CO2/Temp Recessed

The new Senva CT1 Series comes in our newly engineered enclosure making it the most attractive and quickest-installed CO2 sensor on the market. Designed with a selectable analog output and a variety of thermistor options allows flexibility on-site and ease of ordering. It mounts easily in any junction box or it can be unobtrusively mounted directly to drywall using Senva’s built-in drywall clamps. Save installation time and energy costs with this versatile product.

VOC Recessed Value

VOC Recessed Value

The VT0R is capable of sensing thousands of VOC’s coming from sources such as paints, glues, cleaners, alcohol, building products, smoke, and myriad other harmful or offensive gases. It’s ability to sense these contaminants in addition to breath and other bodily functions makes it the preferred alternative or compliment to CO2 occupancy sensing. The VT0R Value Series ensures that odor and ventilation issues are never a topic of conversation. An array of analog outputs and thermistor options accommodate any installation and keep occupants breathing easy.

VOC Duct

VOC Duct

The VT0D is capable of sensing thousands of VOC’s coming from sources such as paints, glues, cleaners, alcohol, building products, smoke, and myriad other harmful or offensive gases. It’s ability to sense these contaminants in addition to breath and other bodily functions makes it the preferred alternative or compliment to CO2 occupancy sensing. The VT0D Value Series ensures that odor and ventilation issues are never a topic of conversation. An array of analog outputs and thermistor options accommodate any installation and keep occupants breathing easy.

TotalSense RH/T/PIR Wall

TotalSense RH/T/PIR Wall

The TotalSense Humidity version is designed for quick-installation and complete flexibility. With options for analog or BACnet/Modbus connectivity, four display options, various thermistors, sliders, and pushbuttons, it can be configured for any job. Motion detection (PIR) can initiate ventilation upon occupancy, providing air exchanges the instant people are present (in addition to monitored elevated CO2 levels.) This technology provides a much faster trigger for ventilation allowing for cleaner and safer indoor spaces while still saving energy. PIR and ambient light sensors can also be utilized for light harvesting for additional energy savings and code compliance. The TotalSense Series also includes a comprehensive selection of IAQ sensors. For options including CO2, TVOC, or PM, see the "indoor air quality" section.

RH/Temp Recessed/Wall

RH/Temp Recessed/Wall

The new Senva HT1 Series comes in our newly engineered enclosure making it the most attractive and quickest-installation humidity sensor on the market. Designed with a universal analog output and a variety of thermistor options allows flexibility on-site. It mounts easily in any junction box or it can be unobtrusively mounted directly to drywall using Senva’s built-in drywall clamps. Save installation time and energy costs with this versatile product.

Wet Differential Pressure Senor

Wet Differential Pressure Senor

Senva’s PW31 Series is designed to streamline installation and provide maximum accuracy. Options for standalone transducer or 3-valve and 5-valve bypass assemblies allow flexibility and save time on installation and commissioning. The single-diaphragm element is temperature compensated to provides superior ±0.25% accuracy. The single-diaphragm silicon piezoresistive differential pressure element is engineered to measure only the differential pressure, so is not affected by high gauge pressures. It’s compact, light, and rugged structure combined with IP65 stainless steel construction make it ideal for most installations and capable of withstanding the most rugged environments.