Currrent Sensor - Fixed (Go/No Go)

Applications

  • Monitoring on/off status of electrical loads
  • Monitoring direct-drive units, exhaust fans, and other fixed loads
  • Verifying lighting run times

Description

Fixed threshold trip point detects the presence of current above low trip point to provide cost-effective status monitoring unit vents, exhaust fans, recirculation pumps, and other fixed loads where belt loss is not a concern.

Product     Price   Quantity
C-2200 Current Switch. Go/no, N.O.,Mini Split-core, 0.5-50A range   $ 63.00
C-2300 Current Switch, Go/No, N.O., Split-core, 0.35-200A   $ 51.00
C-2300HV Current Switch, Go/No, N.O., Split-core, 0.35-100A,120 VAC   $ 86.85
C-1200HV Current Switch,go/no, N.O.Mini solidcore,0.25-50A;120VAC   $ 69.00
C-1200 Current Switch,Go/no, N.O.,Mini solidcore, 0.25-50A range   $ 31.50
C-1300 Current Switch,Go/no, N.O.,Solid-core, 0.25-50A range   $ 36.00
CR3-12 Command Relay, N.O., 12 VDCcoil   $ 25.50
CR3-24 Command Relay, N.O., 24 VAC/DCcoil   $ 25.50
CR4-12 Command Relay, N.C., 12 VDCcoil   $ 25.50
CR4-24 Command Relay, N.C., 24 VDCcoil   $ 25.50

CLICK ON LISTED ITEM FOR SPECIFICATIONS.

List prices shown; trade pricing appears on orderpad for Senva Trade Accounts.
For qualified trade pricing, please contact us at 866-660-8864.
Oregon has no sales tax.

Ideal for ECM motors

  • Trip point operation is tuned to prevent false trips when used with electronically cummated motors 

Reliable and cost-effective

  • Solid-state—no moving parts to fail
  • Less expensive than 277V relays for lighting status
  • More reliable for status than relays across auxiliary contacts
  • Industry leading 7 year limited warranty

 

ORDERING INFORMATION
Split Core Min (on) Max A N.O. Output*
C-2300 0.35A 200A 1.0A@30VAC/DC
C-2300HV 0.35A  100A 0.2A@120VAC
Split Core - Mini Min (on) Max A N.O. Output*
C-2200 0.5A  50A 1.0A@30VAC/DC
Solid Core Min (on) Max A N.O. Output*
C-1300 0.25A 50A 1.0A@30VAC/DC
Solid Core - Mini Min (on) Max A N.O. Output*
C-1200 0.25A 50A 1.0A@30VAC/DC
C-1200HV 0.25A 50A 0.2A@120VAC
Command Relay Contact rating Coil
CR3-24 N.O. 10A@125VAC 24VAC/DC, 15mA nom.
CR4-24 N.C. 10A@125VAC 24VAC/DC, 15mA nom.
CR3-12 N.O. 10A@125VAC 9-12VDC, 30mA nom.
CR4-12 N.C. 10A@125VAC 9-12VDC, 30mA nom.
Specifications
Standard Output Rating 1.0A@30VAC/DC
Line Voltage Output Rating 0.2A@120VAC (-HV MODELS ONLY)
Output Type NO, solid-state FET
Temperature Rating -15-60 ° C
Insulation Class 600V RMS. For use on insulated conductors only!
Insulation Class Use minimum 75 ° C insulated conductor
Sensor Power Induced
Frequency Range 50/60Hz